The current page does not exist in the target language.

Do you want to change the language and go to the home page or do you want to stay on the current page?

Change Language
Solar Energy
Installers & Partners

Fronius Primo

The communicative inverter for optimised energy management.

With power categories ranging from 3.0 to 8.2 kW, the Fronius Primo perfectly complements the SnapINverter generation. This single-phase, transformerless device is the ideal inverter for private households. Its innovative SuperFlex Design provides maximum flexibility in system design, while the SnapINverter mounting system makes installation and maintenance as easy as possible. The communication package included as standard with WLAN, energy management, numerous interfaces, and much more besides, makes the Fronius Primo a communicative inverter for owner-occupiers.
Please choose your desired product.

Product details

INDGANGSDATA

Antal MPP-trackere
2,0
Maks. indgangsstrøm (Idc maks)
18 / 18 A
Maks. kortslutningsstrøm modulfelt
27 / 27 A
DC indgangsspændingsområde (Udc min - Udc maks)
80 - 1000 V
Forsyning startspænding (Udc start)
80,0 V
Nominel indgangsspænding (Udc,r)
710,0 V
MPP-spændingsområde (Umpp min - Umpp maks)
240 - 800 V
Anvendeligt MPP-spændingsområde80 - 800 V
Antal DC-tilslutninger2 + 2
Maks solcelle-generatoreffekt (Pdc maks)
7,5 kWpeak

UDGANGSDATA

Nominel AC-effekt (Pac,r)
4600,0 W
Maks. udgangseffekt (Pac maks)
5000,0 VA
AC-udgangsstrøm (Iac nom)
21,7 A
Nettilslutning (Uac,r)
1~ NPE 220/230 V
AC spændingsområde (Umin - Umaks)
180 - 270 V
Frekvens (fr)
50 / 60 Hz
Frekvensområde (fmin - fmaks)
45 - 65 Hz
Klirfaktor
< 5 %
Effektfaktor (cos φac,r)
0,85 - 1 ind./cap.

GENERELLE DATA

Måling (højde)645,0 mm
Måling (bredde)431,0 mm
Måling (dybde)204,0 mm
Vægt21,5 kg
BeskyttelsesartIP 65
Beskyttelsesklasse1,0
Overspændingskategori (DC / AC) 1)
2 / 3
Standby-forbrug< 1 W
InverterkonceptUden transformer
KølingStyret luftkøling
MonteringIndendørs og udendørs montering
Omgivelsestemperatur-område-40°C - +55°C
Tilladt luftfugtighed0 - 100 %
Maks. højde over havets overflade 2)
4.000 m
Tilslutningsteknologi DC4x DC+ og 4x DC-skrueklemmer 2,5 - 16 mm²
Tilslutningsteknologi AC3 polede AC-skrueklemmer 2,5 - 16 mm²
Certifikater og opfyldelse af normerDIN V VDE 0126-1-1/A1, IEC 62109-1/-2, IEC 62116, IEC 61727,<br /> AS 4777-2, AS 4777-3, G83/2, G59/3, CEI 0-21, VDE AR N 4105

VIRKNINGSGRAD

Maks. virkningsgrad (solcelle - strømnet)98,1 %
Europ. virkningsgrad (ηEU)97,1 %
η ved 5 % Pac,r 3)
80,8 / 82,5 / 82,5 %
η ved 10 % Pac,r 3)
89,6 / 94,8 / 93,1 %
η ved 20 % Pac,r 3)
93,4 / 97,2 / 96,2 %
η ved 25 % Pac,r 3)
94,1 / 97,3 / 96,8 %
η ved 30 % Pac,r 3)
94,7 / 97,4 / 97,0 %
η ved 50 % Pac,r 3)
95,8 / 97,9 / 97,7 %
η ved 75 % Pac,r 3)
96,1 / 98,0 / 97,9 %
η ved 100 % Pac,r 3)
96,2 / 97,9 / 97,9 %
MPP-tilpasningsvirkningsgrad> 99,9 %

BESKYTTELSESANORDNINGER

DC-isolationsmålingJa
Funktionsmåde ved overbelastningArbejdspunktsforskydning, effektbegrænsning
DC-afbryderJa
PolaritetsbeskyttelseJa

INTERFACES

WLAN / ethernet LANFronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6 indgange og 4 digitale ind-/udgangeTilkobling til rundstyringsmodtager
USB (type-A bøsning) 4)
Datalogging, inverter-update pr. USB-stik
2x RS422 (RJ45-stik) 4)
Fronius Solar Net
Meddelelsesudgang 4)
Energimanagement (potentialfri relæudgang)
Datalogger og webserverIntegreret
Ekstern indgang 4)
Forbindelse S0-tæller / analyse overspændingsbeskyttelse
RS485Modbus RTU SunSpec eller tællertilslutning

SnapINverter technology

The SnapINverter generation of inverters features a simple, standardised mounting system, making installation and maintenance easier than ever. A special feature in the design of the device is that the connection area is separate from the power stage set compartment, with both being installed separately. The remarkably light connection area and all its cabling is fitted to the wall first, followed by the power stage set. The innovative hinged system makes installation and servicing extremely user-friendly. The inverter is simply placed in the wall bracket and then secured. This means that it is not necessary to remove the entire inverter for servicing, just the power stage set. All the cabling remains in place.

Integrated data communication

We are the first inverter manufacturer to offer a data communication package with fully integrated datalogging, WLAN, Ethernet, energy management, web server and a range of interfaces. The inverter is connected to the internet by network cable or WLAN - without additional cabling - and grants you the perfect overview of how the PV system is operating. Connection to third-party components is provided by means of interfaces such as Modbus TCP SunSpec, Modbus RTU SunSpec or Fronius Solar API (JSON). The open interfaces can also be operated in parallel to the Fronius Solar.web.

SuperFlex Design

The Fronius SuperFlex Design is an ingenious combination of technical performance attributes that make designing your PV system not only extremely simple, but also incredibly flexible. The key performance factors of the SuperFlex Design are two MPP trackers, together with a high system voltage and wide DC input voltage range. Every DC input, and therefore every MPP tracker, is able to accommodate the entire nominal output of the inverter. Regardless of whether the inverter has to cope with different roof orientations, shading of one or two strings, or the use of residual modules: a Fronius inverter featuring integrated SuperFlex Design will satisfy every conceivable operational PV system planning scenario using just a single inverter model.

Dynamic Peak Manager

The Dynamic Peak Manager is a new MPP tracking algorithm that dynamically adapts its behaviour when searching for the optimal operating point. Its special feature is that the Dynamic Peak Manager automatically checks the entire characteristic curve on a regular basis and finds the global Maximum Power Point (GMPP), even in partial shade.

Smart Grid Ready

Fronius inverters are ready for the Smart Grid of tomorrow. The inverters are optimally equipped to meet the technical requirements of grids in the future. A series of smart functions, known as Advanced Grid Features, are built into the devices. They include a number of control functions for optimum feed-in of reactive power and effective power. These functions are designed to enable stable grid operation even when the PV system density is very high and to prevent unwanted interruptions to feed-in and associated yield losses if grid parameters exceed the thresholds. Fronius inverters therefore help to guarantee the yield of a PV system. Furthermore, where feed-in limits are imposed, Fronius inverters can provide dynamic feed-in control with self-consumption taken into account. Just connect the meter and set the feed-in limit!

Zero feed-in

Today, an increasing number of grid operators in various countries are stipulating a PV power feed-in limit as a precondition before a system is connected to the grid. With dynamic power reduction, Fronius is offering a solution for optimum feed-in management. The Inverter supplies the household consumers with energy first and then reduces the system Output to the maximum energy feed-in permitted by the grid operator. With Fronius inverters, zero feed-in is also a possibility thanks to this function, meaning that no PV power is fed into the grid. The relevant requirements of the grid operator can be fulfilled by simply enabling a Setting on the inverter's web interface.

Active Cooling

Active cooling technology relies on one or more fans, which not only avoid hot spots, but also regulate the air circulation inside the inverter, thus keeping the temperature of the power electronics low. This has a positive effect on the service life of the devices, optimises yields and reduces costs. At Fronius, active cooling is supplied as standard in all devices.

Your contact person

+43 (7242) 241 5262
+43 (7242) 241 5262 ci-genvavat@sebavhf.pbz

Fodnoter til de tekniske data

1) I henhold til IEC 62109-1.  

2) Ubegrænset spændingsområde. 

3) Og ved Umpp min / Udc,r / Umpp maks.

4) Leveres også i light-versionen. 

 

* Isc pv = Isc max ≥ Isc (STC) x 1,25 according to e.g.: IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021.